Zoning Bylaw 03-2016 - Accessory Buildings
3. Accessory buildings shall meet the locational requirements as contained in the following Table:
Zone (District) |
Front Yard Minimum (1) |
Rear yard, minimum |
Side yard minimum |
Building height, maximum |
Maximum site coverage (total cumulative site coverage of all accessory buildings) (2)(3)(4)
|
|||
Lakeshore site |
Other site |
Lakeshore site |
Other site |
Abutting street |
Other site |
|||
RA |
3 meters |
6 meters |
6 meters |
.76 meters |
3 meters |
1.5 meters Liq. or .76 meters if located fully In rear yard |
12 metres |
84 sq. m except on sites exceeding 460 sq m in area, , up to 18% of site coverage is permitted. |
RA1, R1 R2 |
3 meters |
6 meters |
6 meters |
.76 meters |
3 meters |
1.5 meters Liq. or .76 meters if located fully In rear yard |
9 meters |
84 sq. m except on sites exceeding 460 sq m in area, where up to 18% of site coverage is permitted.
In any case, an absolute total maximum site coverage for accessory buildings on any site cannot exceed a maximum of 240 sq m. |
C1 |
Same as principal building |
Same as principal building |
15 meters |
3 meters |
Same as principal building |
Same as principal building |
9 meters |
Not to exceed site coverage of the principal building |
CS |
Same as principal building |
Same as principal building |
Same as principal building |
Same as principal building |
Same as principal building |
Same as principal building |
9 meters |
Not to exceed site coverage of the principal building |
IL l J (see footnote 3) |
n/a |
Same as principal building |
same as principal building |
Same as principal building |
Same as principal building |
Same as principal building |
9 meters |
Not to exceed site coverage of the principal |
RC |
Same as principal building |
Same as principal building |
15 meters |
Same as principal building |
Same as principal building |
Sarne as principal building |
9 meters |
Not to exceed site coverage of the principal building |
R3 |
3 m |
6 m |
6 m |
0.76 m |
3 m |
1.5 m or .0.76 m if fully located in the rear yard |
4 m |
54 sq m |
|
- In all Residential Zones, if, in the opinion of the Development Officer, an accessory building will interfere with established site lines to the lake or fronting street from the principal building of the site or neighboring sites, the accessory building will be required to meet the setback requirements of the principal building.
- Total cumulative building floor area of all accessory buildings on a site, with the exception of aircraft hangars, may not exceed the building floor area of the principal building.In residential zones, notwithstanding the site coverage of the principal building, the cumulative site coverage of all accessory buildings may total up to 54 sq m.
- Accessory buildings for value added processing uses are required to meet setback requirements of Table 8.1 of the District Official Community Plan.”
- Notwithstanding preceding sub-section 5.5.3 in ay residential zone an accessory building not exceeding 54 sq. meters in area may be constructed regardless of the area of the principal building.